The COST $$ of Multiplex A614 PUMPS
with Various PULSEGUARD Dampers

Multiplex pumps, overlapping displacemen, pressure interception.
System response is high frequency pressure pulsation.
Isolate pump-system, "interception" guarantees smoothness.
Multiplex A614 PUMPS

GO TO General/Prices/Installation/etc. Pages Mulitplex A614 Pumps with Pulsation Dampers

420 rpm, 5 plungers 50mmD 100mmStk. 400L/M 4.5 M/sec. 2" Sch 160 pipe, 190ml pulse Vol. (say 105 USGM) 35 Hz. frequency @ +&- 30 bar on a 200 Bar nominal (say 3000psi) system. With a 5 Litre (1.25 Gal) single flange Accumulator.

2 pcs. 316 2" T sch 160@ $195
5 pcs. 316 2" 1500# @ $115
8 Hrs fit-up and welding @ $62.50/hr.
4.5 hrs. NDE QA & Hydro $280
300 in3 SS wetted Acc. C/W 2" 1500# face $1,969

3.) Total $3,714

Realized a "T" could be save by connecting Pi to the second port of a standard damper, they saved themselves a bunch of money. But Td off line it still didn't dampen. The dead branch leg couldn't respond in 0.014 of a second, & Pi couldn't detect any pulse! 1 "T" & 3 Flgs. $440
5 hrs fit and weld $315
Standard twin port all SS Flo-Thru Damper, Flgd.

2.) Total $2,530

Finally - the disturbance was directed through a one third sized, true flo-thru. 3 ported DAMPER
RESULTS: Pressure pulsation less than 1.5 Bar.
Accumulator volume reduces flow fluctuation, --but dampers intercept system pressure response.
No Ts no Flgs. $0,000
PipeHugger TW Flgd. C/W P.I. tap $1,825
Total $1,825
There is always more than one pump cylinder sucking, always 2 blowing, the check valves of each are influenced by the other, high frequency pressure pulsation is the system response. Installing an intercepter damper between pump and system isolates forcing action from the system response, pressure pulsation and flow fluctuation are cured.

Because flow is so slow, there is time to flow up, come to a stop, and flow back down a "T" - on the other hand, whatever the residual pressure pulsation level is, it will fly straight past a "T".

Mass of liquid in a pipe is transferred at not above 180 inches/sec or say 460 cm/sec
Pressure is 300 times faster than flow!

Pressure in a fluid travels at, Mach 1 (in Air)
In harder substances (liquid) is transferred at up to 4000 MPH, or say 140,000 cm/sec.

CONCLUSION:- With 300% greater efficiency, because flow fluctuations & pressure pulsation are forced to see the inside of PULSEGUARD PULSE DAMPERS, are more compact vessels and DO MORE WORK FOR A LOWER COST
hence the saying:-

Dampers that do, flow goes through, BUT pressure pulsation is caught

DON'T FORGET! This takes you straight back to the beginning -- don't use back, back, back Explorer button.

Return to the top
Multiplex pumps with all dampers
Return to the beginning of PulseGuard, pulsation dampeners

Selecting Pulsation Dampeners for Different Pump Systems.
Flow through pulsation dampers are at least 3 times more efficient than T off line accumulators.
Dampeners that do, flow goes through, but pressure pulsation does not.
PulseGuard Pulsation DampersThe Smooth Flow People

Call Toll Free 1-888-DAMPERS (326-7377) / See also: Pulsation-Dampeners.com for a pulsation dampener.


Fluid Flow Control Fluid-Flow-Control.com The Fluid Flow Control Source Pumps Accumulators Filters Dampers Heat Exchangers Valves Mixers P.I. / Pressure Indicators Controls Meters Vessels