Even with the exceptional PACKED PLUNGER PUMP SUCTION LIFT CAPABILITY from minimum dead volume, slow long stroke and small plunger diameter, there are still - FILLING PROBLEMS - galore! |
|
TECH NOTE: It is not necessary to read these highlighted sections |
|
| PROBLEM A blowing agent (like pentane) is chilled and transferred into a supply tank. It warms a little, and the vapor pressure provides a supply "suction head pressure". The liquid is at vapor pressure! The liquid will only move to the pump suction check valve if the pressure at the check valve is lower than where it came from. So at the pump it is below vapor/our pressure. The pump doesn't fill. The height of the tank is enough head to over come the flow friction, most of that benefit is lost by further warming as it travels the pipe. ANSWER 1) Cooling jacketed damper brings temperature below vapor/our pressure @ temp. 2) The damper sized to recover 96% of the suction mass acceleration head loss. 3) Damper with flow through to save flow reversal loss (that occurs with a "T" connection). AND which keeps the temperature constant - warm in - cool out. |
Click on dampers or pump for associated pages |
Click on dampers or pump for associated pages |
RESULTS |
First address the suction system, no pump can give you smooth flow unless it can fill properly Dampers that do, flow goes through, Pressure problems do not. |
|